Individual slide processing
Each slide sits in an individual compartment. Nozzles apply fresh reagent to limit cross-contamination.

Automated slide staining
A slide-staining platform with a dedicated compartment for each slide and fresh reagent delivered by precision nozzles. The selected instrument configuration determines the available microbiology or haematology protocols.
In the daily workflow
Each slide sits in an individual compartment. Nozzles apply fresh reagent to limit cross-contamination.
Gram, Ziehl-Neelsen, Kinyoun, fluorescence and selected haematology stains. Available protocols vary by configuration.
Evaluation covers the instrument, staining reagents, cleaning solution and quality-control materials.
Technical profile
Two types of the same system

One staining protocol. One row of reagents, with a lid on the right-hand side.
Gram · Fluorescence · Ziehl-Neelsen · Kinyoun · Wright-Giemsa · May Grünwald-Giemsa

2 or 3 staining protocols in one system, in parallel. Two rows of reagents, with lids on both sides.
Gram + Fluorescence · Gram + Ziehl-Neelsen + Kinyoun · Fluorescence + Ziehl-Neelsen + Kinyoun
Ordering references
Microbiology
Haematology
Source: DX-300 brochure 06/2025, page 4, “Devices”.
Manufacturer-stated cycle times
Capacity up to 20 slides
Capacity up to 10 slides
Capacity up to 20 slides
Capacity up to 20 slides
Capacity up to 20 slides
Capacity up to 20 slides
Source: DX-300 brochure 06/2025. Times vary by staining program.
DOCUMENTATION
The June 2025 brochure lists Gram, Ziehl-Neelsen, Kinyoun, Fluorescence, Wright-Giemsa and May Grünwald-Giemsa, depending on the model. Gram: 6 minutes for 10 slides or 11 minutes for 20. Ziehl-Neelsen: up to 10 slides, 11 minutes for 10. Kinyoun: 14/19 minutes for 10/20 slides. Fluorescence: 10/15 minutes. Wright-Giemsa: 6/9 minutes. May Grünwald-Giemsa: 15/17 minutes. The selected configuration determines the available protocols.
Ask about this productFROM THE DEMONSTRATIONS
The DX-300 demonstration shows integrated ventilation: reagent vapours pass through a carbon filter before exhaust. Confirm installation requirements, filter maintenance and exact model with Medical Trade.
The demonstration shows staining-program customisation for laboratory needs. The June 2025 brochure specifies storage for up to three custom programs.
The DX-300 presentation shows the stainer combined with a slide warmer and integrated cleaning/drying functions. The brochure also describes an integrated slide warmer and cleaning. Follow the required maintenance and laboratory control procedures.
Ask about the workflowMEDICAL TRADE INTERNATIONAL